EasyManua.ls Logo

EDM Solution 862 - Sensor Watch Time

Default Icon
262 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
206
Solution 862
Installation Manual
Sensor Watch Time
LOCATION 408 - 409
00
Location Description
408
Increments Of Days (Tens Digit)
409
Increments Of Days (Units Digit)
Table 111: Sensor Watch Time Locations
The time set in these two locations determine how many days (0-99) a zone may remain sealed
before registering as a fault. This feature is only active when the system is in the disarmed
state. If a zone programmed for sensor watch has not become unsealed and reset during this
time, the
FAULT
indicator will illuminate. Refer to Fault Descriptions on page 64 for further
information on sensor watch faults. Refer to Zone Options 1 on page 167 for programming
zones for sensor watch.
The sensor watch time counter is only active whilst the control panel is disarmed. Therefore, if
the system is only disarmed for 8 hours a day and the sensor watch time is programmed for 1
day, a zone that is programmed for sensor watch will register a sensor watch fault if not
triggered during the disarmed state within 3 days.
This feature would be useful in a situation where someone has moved objects in the view of the
detector, blocking out the detector from picking up movement.
Codepad Lockout Time
LOCATION 410
Location Description
410
Increments Of 1 Minute (0 - 15 Minutes)
Table 112: Codepad Lockout Time Locations
All codepads will be locked out for the specified time programmed if an invalid code has been
entered more times than allowed by the code retry attempts programmed in "LOCATION 356"
on page 185. If the Codepad Lockout Time is programmed as zero, no codepad lockout will
occur.