The programming options of the control panel are stored in a non-volatile EPROM. This
memory will hold all the relevant configuration and user specific data even during a total
power loss.
The data retention time is as long as ten years without power; therefore, no reprogramming will
be required after powering the control panel down.
The data can be changed as many times as required without the need for any additional
specialised equipment. This memory is laid out in numerous locations, each of which holds the
data for a specific function.
15 is the maximum value that can be programmed into any location.
In general, the entire programming sequence will consist of nominating the required location
number and then enter or change the current data. You will repeat this procedure until all the
data has been programmed to suit your requirements. The factory default settings have been
selected for reporting to the monitoring station in the Contact ID Format.
The Installers Code only gives access to the Installer's Programming Mode and does NOT arm
and disarm the system. Installer’s Programming Mode can not be entered when the system is
armed, or at any time during siren run time.
Programming of the
Solution 862
control panel can be carried out via any of the following
three methods.
•
•
•
Example
Remote Codepad
Hand Held Programmer (CC814)
Alarm Link Upload/Download Software (CC816)
Primary Telephone Number For Receiver 1
LOCATION 000 - 015
0000000000000000
LOCATION 000
LOCATION 004
LOCATION 001
LOCATION 015