Installation Manual
System Status - Low Battery Report
LOCATION 352 - 353
1
Location Description
352
System Status – Low Battery Reporting Code (Tens Digit)
353
System Status – Low Battery Reporting Code (Units Digit)
Table 95: System Status – Low Battery Report Locations
A "Battery Test Failure" report (Contact ID Event Code 309) will be transmitted to the base
station receiver when the systems battery voltage falls below 10.5 volts or when a dynamic
battery test detects a low capacity battery.
The control panel continually monitors the battery voltage. Refer to Fault Descriptions on
page 64 for more information. A dynamic battery test is performed every time the system has
been armed as well as every four hours from power up of the control panel.
If a "Low Battery" report is not required, program "LOCATION 352 - 353" with a zero.
Outputs 1 – 4 will NOT operate whilst the control panel detects a low battery.
System Status - Low Battery Restore Report
LOCATION 354 - 355
Location Description
354
System Status – Low Battery Restore Report (Tens Digit)
355
System Status – Low Battery Restore Report (Units Digit)
Table 96: System Status – Low Battery Restore Report Locations
A "Low Battery” restore report will be transmitted if the back up battery has been restored the
next time the system has been armed, or when the next dynamic battery test reports the battery
test is OK.
If a "Low Battery Restore" report is not required, program "LOCATION 354 - 355" with a
zero.