System Operations 55
Method Two
How To Arm The System In STAY Mode 1
1.
Hold down the
button until two beeps are heard.
The
STAY
indicator will illuminate and exit time will now commence.
Any zones that have been programmed to be automatically isolated in STAY Mode 1
will begin to flash until exit time expires. At the end of exit time, the
ZONE
indicators
will extinguish and the codepad will give one short beep.
If a zone is not sealed at the end of exit time, the zone will be automatically isolated and will
be constantly illuminated on the remote codepad. The zone will become an active part of the
system again as soon as it has resealed (i.e. If a window is left open after exit time has expired,
the window will not be an active part of the system until it has closed. Opening the window
after exit time has expired will cause an alarm condition).
Forced Arming
The feature of arming the system when a zone is not sealed is known as forced arming. Refer
to Zone Options 2 on page 171 to enable forced arming for each zone.
If the
STAY
indicator does not illuminate and a long beep is heard when attempting to arm the
system in STAY Mode 1, forced arming is not permitted. If this is the case, you must ensure
that all zones are sealed or manually isolated before you can arm the system.
Electronics Design and Manufacturing Pty Limited ISSUE130