14
Momentary Arm and Disarm In AWAY Mode
If this option has been selected, the system will either arm or disarm from AWAY Mode when
using the momentary keyswitch input.
Momentary Arm In AWAY Mode
If this option has been selected, the system will arm in AWAY Mode when using the
momentary keyswitch input. Disarming the system will not be permitted via the keyswitch
zone if this option has been selected.
Momentary Disarm From AWAY Mode, STAY Mode 1 Or STAY Mode 2
If this option has been selected, the system will disarm from either AWAY Mode, STAY Mode
1 or STAY Mode 2 when using the momentary keyswitch input. Arming the system will not
be permitted via the keyswitch zone if this option has been selected.
Momentary Arm and Disarm In STAY Mode 1
If this option has been selected, the system will arm or disarm in STAY Mode 1 when using
the momentary keyswitch input. Arming and disarming the system in AWAY Mode will not
be permitted via the keyswitch zone if this option has been selected.
Momentary Arm In STAY Mode 1
If this option has been selected, the system will arm in STAY Mode 1 when using the
momentary keyswitch input. Arming the system in AWAY Mode or disarming the system will
not be permitted via the keyswitch zone if this option has been selected.
Momentary Disarm From STAY Mode 1 Or STAY Mode 2
If this option has been selected, the system will only disarm the system from STAY Mode 1 or
STAY Mode 2 when using the momentary keyswitch input. Arming the system in STAY
Mode 1, STAY Mode 2 or arming and disarming the system from AWAY Mode will not be
permitted via the keyswitch zone if this option has been selected.
Figure 10: Wiring Diagram For Keyswitch Zone