Solution 862
Installation Manual
4+2 Reporting Format
The 4+2 Express Format will report a Subscriber ID Number followed by an expansion code
and the reporting channel number is transmitted directly after the expansion code.
Subscriber ID Number Expansion Code Channel Number
SSSS A CH
Table 49: Example Reporting In 4+2 Format
New Event 4 + 2 Report Event 4 + 2 Report
Alarm
SSSS AC
H
Alarm Restore
SSSS R C
H
Trouble
SSSS TC
H
Trouble Restore
SSSS TR C
H
Bypass
SSSS BC
H
Bypass Restore
SSSS B
R
C
H
AC Fail
SSSS EA
C
AC Fail Restore
SSSS E
R
A
CR
Low Battery
SSSS LL
B
Low Battery Restore
SSSS L
BR
L
B
Opening Report
SSSS OU
Closing Report
SSSS CU
Test Report
SSSS T
E
O
Program Altered
SSSS P0
Duress
SSSS DD
0
Table 50: 4 + 2 Reporting Format
Code Description Code Description
SSSS
Subscriber ID Number
R
Alarm Restore Code
A
Alarm
TR
Trouble Restore Code
CH
Channel Number
BR
Bypass Restore Code
0
Zero
ER
AC Fail Restore Code 1
st
Digit
T
Trouble
ACR
AC Fail Restore Code 2
nd
Digit
B
Bypass
LR
Low Battery Restore Code 1
st
Digit
E
AC Fail Code 1
st
Digit
LBR
Low Battery Restore Code 2
nd
Digit
AC
AC Fail Code 2
nd
Digit
D
Duress Code 1
st
Digit
L
Low Battery Code 1
st
Digit
D0
Duress Code 2
nd
Digit
LB
Low Battery Code 2
nd
Digit
P
Panic Code 1
st
Digit
OP
Open
PCH
Panic Code 2
nd
Digit
CP
Close
TP
Test Code
U
User Number
Table 51: 4 + 2 Transmission Code Descriptions