52
Solution 862
Installation Manual
System Operations
This section explains the general operations of the system. The operations will explain how to
arm and disarm the system in the various modes, how to isolate zones, initiate codepad alarms
and determine any fault that may occur.
Arming The System In AWAY Mode
Arming the system in AWAY Mode is normally performed when you leave the premises and
require that all zones be activated in a ready state to detect any intrusion.
There are two different methods for arming the system in AWAY Mode. Method one is
standard and will always operate. Method two is optional and needs Option 2 in "LOCATION
429" to be enabled on page 220.
If you require to isolate a zone(s) prior to arming the system in AWAY Mode, refer to Isolating
Zones on page 60.
Single button arming in AWAY Mode will report as user code number 16.
Method One
How To Arm The System In AWAY Mode
1.
Enter your
followed by the button.
Two beeps will be heard and the
AWAY
indicator will illuminate. Exit time will now
commence.
+
Method Two
How To Arm The System In AWAY Mode
1.
Hold down the
button until two beeps are heard.
The
AWAY
indicator will illuminate and exit time will now commence. Refer to Option
2 in "LOCATION 429" on page 220 to enable single button arming in AWAY Mode.
If a zone is not sealed at the end of exit time, the zone will be automatically isolated and will
be constantly illuminated on the remote codepad. The zone will become an active part of the
system again as soon as it has resealed (i.e. If a window is left open after exit time has expired,
the window will not be an active part of the system until it has closed. Opening the window
after exit time has expired will cause an alarm condition).
Forced Arming
The feature of arming the system when a zone is not sealed is known as forced arming. Refer
to Zone Options 2 on page 171 to enable forced arming for each zone.
If the
AWAY
indicator does not illuminate and a long beep is heard when attempting to arm the
system in AWAY Mode, forced arming is not permitted. If this is the case, you must ensure
that all zones are sealed or manually isolated before you can arm the system.
ISSUE130 Electronics Design and Manufacturing Pty Limited