FAULT Indicator
The
FAULT
indicator is used to display that the system has detected a system fault. Refer to
Fault Analysis Mode on page 63 for more information on system faults.
Every time a new system fault has been detected (e.g.:
FAULT
indicator flashing), the codepad
will begin to beep once every minute.
Pressing the
button once will cancel the once a minute beep and acknowledge the fault
(e.g.:
FAULT
indicator on).
Indicator Definition
On
There Is A System Fault That Needs To Be Rectified
Off
The System Is Normal, There Are No Faults
Flashing
There Is A System Fault Waiting To Be Acknowledged
Table 18: FAULT Indicator
Programming Mode
Flashing
These two indicators will flash when the system has entered either Installer’s Programming
Mode or when any Master Code Functions are used.
Off Indicator/Zone Sealed
The indicator will illuminate when the system is in the disarmed state or Installer’s
Programming Mode has been entered and will flash when a zone becomes unsealed during the
disarmed state. The indicator will stop flashing when all zones are sealed.
On Indicator/Zone In Alarm
The indicator will illuminate when the system is armed in
AWAY
Mode and will flash
when an alarm occurs. The indicator will reset once a valid user code has been entered.