When making use of the control panel's dialling and communication features, there are a
number of transmission formats available. Refer to "LOCATION 033" on page 133 to set the
required transmission format for Receiver 1 and “LOCATION 073” on page 136 to set the
required transmission formation for Receiver 2. The
Solution 862
control panel comes
factory default to report in the Contact ID Format.
Contact ID Format
This format can identify hundreds of protection zones by their unique code and provides a
single digit event qualifier and a three digit event code that quickly identifies the condition
being reported.
Subscriber
ID Number Qualifier
Event
Code
Group
Number
Point ID
Number
SSSS Q XYZ GG CCC
Four Digit
Subscriber ID
Number
Event Qualifier, Which Gives
Specific Event Information.
1 = New Event Or Opening
3 = New Restore Or Closing
Event Code
(Made Up Of 3
Hex Digits)
Group Number
(Made Up Of 2
Hex Digits)
Point ID Number
(Made Up Of 3
Hex Digits)
Table 46: Contact ID Format Breakdown
In general, Contact ID reporting format is very simple as most of the Event Codes and Point ID
Codes have been predefined. The base station software usually only has the ability to identify
a zone going into alarm by its Point ID Code and usually pays little attention to the Event
Code.
Refer to "Table 47: Point ID Codes" on page 125 for further information on the
Solution
862
Point ID Codes.