System and Consumer Options 215
System Options 1
LOCATION 424
1
Option Description
1
EDM Smart Lockout Allowed
2
Horn Speaker Monitor
4
Strobe Indications For Radio Arm/Disarm
8
Horn Speaker Beeps For Radio Arm/Disarm
Table 123: System Options 1
EDM Smart Lockout Allowed
1
This feature allows the control panel to remove any zones that are programmed for lockout
dialler from the lockout list while the sirens are running. This feature allows a monitoring
station to receive zone alarm reports from previously locked out zones during siren time. Refer
to Zone Options 1 on page 167 for information on programming zones for lockout dialler and
lockout siren.
Refer to Swinger Shutdown Count For Dialler on page 174 to program the number of times the
zone can report before being locked out.
Horn Speaker Monitor
2
If this option has been selected, the control panel will detect when the horn speaker has been
disconnected from the speaker terminals. The
FAULT
indicator will illuminate when the horn
speaker has been disconnected and will extinguish when the horn speaker has been
reconnected. If an output is required to operate when the horn speaker has been disconnected,
refer to Output Event Type – Horn Speaker Monitor Fail on page 194 for more information.
Strobe Indications For Radio Arm/Disarm
4
This option will allow the strobe to indicate when the system is armed and disarmed when
remotely operating the system via the Solution Wireless On/Off Interface (WE800).
No Of Seconds System Status
3 Seconds
System Disarmed
6 Seconds
System Armed In AWAY Mode
6 Seconds
System Armed In STAY Mode 1
Table 124: Strobe Indications For Remote Operations
Horn Speaker Beeps For Radio Arm/Disarm
8
This option will allow the horn speaker to indicate when the system is armed and disarmed
when remotely operating the system via the Solution Wireless On/Off Interface (WE800).
No Of Beeps System Status
1
System Disarmed
2
System Armed In AWAY Mode
1 Two Tone
Beep
System Armed In STAY Mode 1
Table 125: Horn Speaker Beeps For Remote Operations
Electronics Design and Manufacturing Pty Limited ISSUE130