System Event Timers 209
Auto Disarming Time
LOCATION 418 - 421
0000
Location Description
418
Actual Hour Of The Day (Tens Digit)
419
Actual Hour Of The Day (Units Digit)
420
Actual Minute Of The Day (Tens Digit)
421
Actual Minute Of The Day (Units Digit)
Table 117: Auto Disarming Time Locations
These locations are used to program the actual time of the day that the system will
automatically disarm itself from AWAY Mode, STAY Mode 1 or STAY Mode 2. This time
must be set in 24 hour format (i.e. 10:30 PM would be programmed as 2230).
User code 16 will report when the feature of automatic arming is used.
V1.00 V1.07 The system failed to automatically disarm if the system was not
programmed to automatically arm. To solve the problem, we suggest that
you program the automatic arming time as 25:00 hours if you only require
the control panel to disarm.
Kiss-Off Wait Time
LOCATION 422
Location Description
422
Increments Of 500 ms (500 ms – 8 Sec’s)
Table 118: Kiss-Off Wait Time Location
This location sets the time that the control panel will wait for acknowledgment before
resending the report. This applies only to Contact ID Format and 4 + 2 Express Formats.