Zone Information 167
Zone Options 1
When programming this location, you will notice that there are four options per location. You
may select one, two, three or all four of these options, however, only one number needs to be
programmed. This number is calculated by adding the option bit numbers together. Program a
seven (7) if you require options 1, 2 and 4 simultaneously (i.e. 1 + 2 + 4 = 7).
Option Description
1
Lockout Siren/Lockout Dialler
2
Delay Alarm Reporting
4
Silent Alarm
8
Sensor Watch
1
Table 74: Zone Options 1
Lockout Siren & Lockout Dialler
Lockout means one activation per arming cycle (i.e. A zone programmed for "Lockout" can
only cause the sirens or dialler to operate once).
When the system is next armed, the zone can cause the sirens and dialler to operate once more.
Restore signals will be transmitted when the system has been disarmed.
The
Solution 862
control panel performs lockout different to most other control panels in
that only the first zone to trigger an alarm condition will be locked out. All other zones that are
triggered during the same siren run time will reset when the sirens reset. This prevents an
intruder from triggering all zones then waiting for the sirens to stop before re-entering the
premises.
Example
All zones are programmed for both lockout siren and dialler. Zone 1 is triggered followed by
all other zones causing the sirens to sound and the dialler to report to the base station receiver.
Zone 1 will be the only zone that stops reporting to the base station receiver because of the first
zone to trigger is locked out. The remaining zones will continue to report if they are triggered
again.
Refer to Swinger Shutdown Count For Siren on page 173 to set the number of times the siren
will be allowed to activate before it will be locked out and Swinger Shutdown Count For
Dialler on page 174 to set the number of times the dialler will activate before lockout will take
effect.
Delay Alarm Reporting
This option will allow the reporting of alarms on selected zones to be delayed to allow the user
to enter their code to cancel alarms that are not required to report. All sounding devices (e.g.:
2
horn speaker, strobe and bell outputs) will operate as soon as the alarm condition occurs, but
the dialler will not operate until the delay time in “LOCATION 406 – 407” on page 205 has
expired.