System Reporting Information 185
System Status - Access Denied
LOCATION 356 - 358
6 7
Location Description
356
Code Retries (0–15)
357
System Status – Access Denied Reporting Code (Tens Digit)
358
System Status – Access Denied Reporting Code (Units Digit)
Table 97: System Status – Access Denied Locations
An "Access Denied" report (Contact ID Event Code 421) will be transmitted to the base station
receiver when the number of incorrect code attempts equals the number programmed in
"LOCATION 356". This is an audible alarm. Refer to Option 8 in "LOCATION 425" on page
216 if you require this alarm to be silent.
Restore signals for this event are not transmitted. If an "Access Denied" report is not
required, program "LOCATION 357 - 358" with a zero.
Code Retries
Code retries restricts the amount of times an invalid user code can be used in an attempt to
operate the system. This location sets the number of incorrect code attempts that will cause an
alarm condition. When the number of incorrect code attempts equals the number programmed
in this location, the system will carry out the following;
1.
Activate the sirens, internal screamers and strobes connected to the control panel. Refer
to Option 8 in “LOCATION 425” on page 216 if you require access denied to be silent.
2.
Shutdown all codepads that are connected to the control panel and lock them out for the
time period programmed in “LOCATION 410” on page 206.
3.
Transmit anAccess Denied” (Contact ID Event Code 421) report to the base station
receiver.
Each time the system is armed or disarmed, the counter will be reset. The number of attempts
can be anywhere between 1-15. If you program a zero into “LOCATION 356”, the code
attempts are unlimited and neither of the three points listed above will take place. This
function works when the system is in the armed or disarmed state.