User Codes 153
User Code Priority
There are ten different priority levels that can be allocated to the user code. Each priority level
allows or restricts the functions that different user code holders may perform.
Priority Level Description
0
Arm/Disarm
1
Arm Only
2
Arm/Disarm + Open/Close Report
3
Arm Only + Close Report
4
Arm/Disarm + Code To Isolate
6
Arm/Disarm + Code To Isolate + Open/Close Report
8
Arm/Disarm + Master Code Functions
10
Arm/Disarm + Master Code Functions + Open/Close Report
12
Arm/Disarm + Master Code Functions + Code To Isolate
14
Arm/Disarm + Master Code Functions + Code To Isolate + Open/Close
Report
Meaning Description
Arm/Disarm
If the user code has this option included in the priority level, the user
can arm and disarm the system. A closing report will only occur after
a previous code that has the ability to send an opening report has
disarmed the system.
Arm Only
If the user code has this option included in the priority level, the user
can only arm the system and cannot disarm the system. A closing
report will only occur after a previous code that has the ability to send
an opening report has disarmed the system.
Open/Close Reports
If the user code has this option included in the priority level, the user
will always send open and close reports back to the monitoring station
upon disarming and arming the system. This option requires
Open/Close reports in “LOCATION 333 - 334” on page 179 to be
enabled for it to be effective.
Code To Isolate
If any user code has this option included in the priority level, the
method of standard isolating is disabled from the system and only
user codes with code to isolate selected can isolate zones prior to
arming the system using the method of code to isolate. Refer to
Isolating Zones on page 60 for more information.
Master Code Functions
If any user code has this option included in the priority level, the user
has access to all Master Code Functions.
Table 68: User Code Priority Levels
Once user code priority levels 4, 6, 12 or 14 have been programmed to any of the
available 8 user codes, the method of standard isolating will no longer operate. Only
those user codes with the priority level of 4, 6, 12 or 14 will be able to isolate zones using
the method code to isolate.