System Reporting Information 187
Test Reporting Time
LOCATION 360 - 366
0000 71 0
Location Description
360
Actual Hour Of The Day (Tens Digit)
361
Actual Hour Of The Day (Units Digit)
362
Actual Minute Of The Day (Tens Digit)
363
Actual Minute Of The Day (Units Digit)
364
Test Report Code (Tens Digit)
365
Test Report Code (Units Digit)
366
Repeat Interval In Days
Table 99: Test Reporting Time Locations
A "Test" report (Contact ID Event Code 602) is a specific signal that is transmitted to the base
station receiver and is normally used to test the dialling and reporting functions of the control
panel. Test reports will not be transmitted if the Subscriber ID Number is 0000.
When programming test reports, the control panel needs to know the hour and minute of the
day the report is required, as well as how often to transmit the report. Test reports are reported
on a daily basis ranging from every day to every fifteen days. Refer to "Installer Code
Functions" on page 76 to set the first test report.
If you do not require "Test" reports, program the repeat interval in "LOCATION 366" as
zero.
Example
If you wish to send test reports once every seven days at 11:35 PM, you would program
“LOCATION 360 - 366” as follows:
2335 71 7
Test Reporting Dialler Options
LOCATION 367
Option Description
0
No Report Required
1
Receiver 1
2
Receiver 2
4
Receiver 1 and Receiver 2
8
Receiver 2 Only When Receiver 1 Fails
Table 100: Test Reporting Options Location
This location is factory default to report only to receiver 1. You can select whether the test
reporting options will report on receiver 1, receiver 2, both receiver 1 and receiver 2, receiver 2
only when receiver 1 fails or no reporting at all.