LOCATION 425
0
Option Description
1
Codepad Panic To Be Silent
2
Codepad Fire To Be Silent
4
Codepad Medical To Be Silent
8
Access Denied (Code Retries) To Be Silent
1
2
4
8
Table 126: System Options 2
Codepad Panic To Be Silent
If this option has been selected, a codepad panic alarm or radio remote panic alarm will not
operate the horn speaker, the bell or the strobe outputs. If this option is not selected, all three
outputs will operate after a codepad panic alarm has been activated when the
1
and
3
buttons or the and buttons on the remote codepad are pressed simultaneously.
Selecting this option does not effect the operation of the communication dialler.
If you wish to disable the reporting of the codepad panic alarm, program “LOCATION 337 -
338” on page 180 as zero.
Codepad Fire To Be Silent
If this option has been selected, a codepad fire alarm will not operate the horn speaker, the bell
or the strobe outputs. If this option is not selected, all three outputs will operate after a
codepad fire alarm has been activated when the
4
and
6
buttons on the remote codepad are
pressed simultaneously. Selecting this option does not effect the operation of the
communication dialler.
If you wish to disable the reporting of the codepad fire alarm, program “LOCATION 339 -
340” on page 181 as zero.
Codepad Medical To Be Silent
If this option has been selected, a codepad medical alarm will not operate the horn speaker, the
bell or the strobe outputs. If this option is not selected, all three outputs will operate after a
codepad fire alarm has been activated when the 7
and
9
buttons on the remote codepad are
pressed simultaneously. Selecting this option does not effect the operation of the
communication dialler.
If you wish to disable the reporting of the codepad medical alarm, program “LOCATION 341 -
342” on page 181 as zero.
Access Denied (Code Retries) To Be Silent
If this option has been selected, a codepad tamper alarm will not operate the horn speaker, bell
or the strobe outputs. If this option is not selected, all three outputs will operate after a
codepad tamper alarm has occurred.
Refer to "LOCATION 356" on page 185 to set the number of invalid code retries before an
alarm condition occurs. Selecting this option does not effect the operation of the
communication dialler. If you wish to disable the reporting of access denied reports program
“LOCATION 357 - 358” as zero.
ISSUE130 Electronics Design and Manufacturing Pty Limited