Menu 8 Single Line Descriptions − Digital I/O
Mode: Openloop
Parameter Range Default Type
08.001 Digital I/O 1 State Off (0) or On (1) RO Bit ND NC PT
08.002 Digital I/O 2 State Off (0) or On (1) RO Bit ND NC PT
08.003 Digital Input 3 State Off (0) or On (1) RO Bit ND NC PT
08.004 Digital Input 4 State Off (0) or On (1) RO Bit ND NC PT
08.005 Digital Input 5 State Off (0) or On (1) RO Bit ND NC PT
08.008 Relay 1 Output State Off (0) or On (1) RO Bit ND NC PT
08.011 Digital I/O 1 Invert Not.Inv (0), Invert (1) Not.Inv (0) RW Txt US
08.012 Digital I/O 2 Invert Not.Inv (0), Invert (1) Not.Inv (0) RW Txt US
08.013 Digital Input 3 Invert Not.Inv (0), Invert (1) Not.Inv (0) RW Txt US
08.014 Digital Input 4 Invert Not.Inv (0), Invert (1) Not.Inv (0) RW Txt US
08.015 Digital Input 5 Invert Not.Inv (0), Invert (1) Not.Inv (0) RW Txt US
08.018 Relay 1 Invert Not.Inv (0), Invert (1) Not.Inv (0) RW Txt US
08.020 Digital I/O Read Word 000000000000 to 100000000000 RO Bin ND NC PT
08.021 Digital IO1 Source/Destination A 0.000 to 30.999 10.003 RW Num DE PT US
08.022 Digital IO2 Source/Destination A 0.000 to 30.999 6.038 RW Num DE PT US
08.023 Digital Input 03 Destination A 0.000 to 30.999 6.030 RW Num DE PT US
08.024 Digital Input 04 Destination A 0.000 to 30.999 6.032 RW Num DE PT US
08.025 Digital Input 05 Destination A 0.000 to 30.999 1.041 RW Num DE PT US
08.028 Relay 1 Output Source A 0.000 to 30.999 10.001 RW Num PT US
08.031 Digital I/O 01 mode Input (0), Output (1), FR (2), Pulse (3) Output (1) RW Txt US
08.035 Digital input 5 mode
Input (0), Th.Sct (1), th (2),
Th.NoTr (3), FR (4)
Input (0) RW Txt US
08.041 Keypad Run Button State Off (0) or On (1) RO Bit ND NC PT
08.042 Keypad Auxiliary Button State Off (0) or On (1) RO Bit ND NC PT
08.043 24V Supply Input State Off (0) or On (1) RO Bit ND NC PT
08.044 Keypad Stop Button State Off (0) or On (1) RO Bit ND NC PT
08.051 Keypad Run Button Invert/Toggle Not.Inv (0), Invert (1), Toggle (2) Not.Inv (0) RW Txt US
08.052 Keypad Auxiliary Button Invert/Toggle Not.Inv (0), Invert (1), Toggle (2) Not.Inv (0) RW Txt US
08.053 24V Supply Input Invert Not.Inv (0), Invert (1) Not.Inv (0) RW Txt US
08.061 Keypad Run Button Destination 0.000 to 30.999 0.000 RW Num DE PT US
08.062 Keypad Auxiliary Button Destination 0.000 to 30.999 0.000 RW Num DE PT US
08.063 24V Supply Input Destination 0.000 to 30.999 0.000 RW Num DE PT US
08.081 DI1 Control 0 to 26 0 RW Num US
08.082 DI2 Control 0 to 26 0 RW Num US
08.083 DI3 Control 0 to 26 0 RW Num US
08.084 DI4 Control 0 to 26 0 RW Num US
08.085 DI5 Control 0 to 26 0 RW Num US
08.091 DO1 Control 0 to 21 0 RW Num US
08.098 Relay 1 Control 0 to 21 0 RW Num US
08.121 DI/O 01 Source/Destination B 0.000 to 30.999 RO Num DE NC PT US
08.122 DI/O 02 Source/Destination B 0.000 to 30.999 RO Num DE NC PT US
08.123 DI 03 Destination B 0.000 to 30.999 RO Num DE NC PT US
08.124 DI 04 Destination B 0.000 to 30.999 RO Num DE NC PT US
08.125 DI 05 Destination B 0.000 to 30.999 RO Num DE NC PT US
08.128 Relay 01 Source B 0.000 to 30.999 RO Num ND NC PT US
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr Character parameter Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP Slot, menu, parameter
Num Number parameter DE Destination ND
No
default value
RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS