Parameter 11.064 Product Identifier Characters
Short description Displays the product identifier characters
Mode Open‑loop
Minimum 1295134768 Maximum 2147483647
Default Units
Type 32 Bit Volatile Update Rate Power-up write
Display Format String Decimal Places 0
Coding RO, ND, NC, PT
The drive model and rating can be identified as AAAAnnnpppppBBBBCCCCDDDD where each section of the model identifier is taken from a
parameter. 'AAAA', 'BBBB', 'CCCC' and 'DDDD' is alpha-numeric characters. 'nnn' and 'ppppp' are decimal digits.
The drive model and rating can be identified as AAAA B nnnppppp CCCC DD EE FFF where each section of the model identifier is taken from a
parameter. AAAA, B, CCCC, DDDD, EE and FFF are alpha-numeric characters. nnn and ppppp are decimal digits.
Section of identifier Parameter
AAAA ProductIdentifierCharacters (11.064)
nnn Framesizeandvoltagecode (11.065)
ppppp Drivecurrentrating (11.068)
CCCC AdditionalIdentifierCharacters1 (11.091)
DDEE AdditionalIdentifierCharacters2 (11.092)
FFFB AdditionalIdentifierCharacters3 (11.093)
ProductIdentifierCharacters (11.064) as defined in the table below.
Digits Meaning
3 to 0 Product identifier (e.g. Mxxx or Ixxx)
Framesizeandvoltagecode (11.065)is split into two fields as defined in the table below.
Digits Meaning
2 to 1 Frame size.
0 Voltage code (1 = 110V, 2 = 230V, 4 = 400V, 5 = 575V, 6 = 690V)
Drivecurrentrating (11.068) is as defined in the table below.
Digits Meaning
4 to 0 Drive current rating (i.e. 00133 = 13.3A)
Example
The model number M101-04200133 A101 00 AB100 would be displayed in parameters as follows
Parameter Value
ProductIdentifierCharacters (11.064) M101
Framesizeandvoltagecode (11.065) 042
Drivecurrentrating (11.068) 00133
AdditionalIdentifierCharacters1 (11.091) A101
AdditionalIdentifierCharacters2 (11.092) 00AB
AdditionalIdentifierCharacters3 (11.093) 100-
Parameter 11.065 Frame size and voltage code
Short description Displays the frame size and voltage code
Mode Open‑loop
Minimum
0
(Display: 000)
Maximum
999
(Display: 999)
Default Units
Type 16 Bit Volatile Update Rate Power-up write
Display Format Lead Zero Pad Decimal Places 0
Coding RO, ND, NC, PT
See ProductIdentifierCharacters (11.064).
Parameter 11.066 Power Stage Identifier
Short description Displays the power stage identifiers within the drive
Mode Open‑loop
Minimum 0 Maximum 255
Default Units
Type 8 Bit Volatile Update Rate Power-up write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT, BU