A drive can be made into a derivative drive by adding a derivative customisation image. The derivative software should specify a derivative identifier
which is put into DriveDerivative (11.028) at power-up. Each derivative should have a unique identifier.
Parameter 11.029 Software Version
Short description Displays the software version in the drive
Mode Openloop
Minimum 0 Maximum 99999999
Default Units
Type 32 Bit Volatile Update Rate Power-up write
Display Format Version Decimal Places 0
Coding RO, ND, NC, PT
SoftwareVersion (11.029) displays the drive control board software version number in the form ww.xx.yy.
Parameter 11.030 User Security Code
Short description Defines the user security code of the drive
Mode Openloop
Minimum 0 Maximum 9999
Default Units
Type 32 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, ND, PT
Defines the user security code of the drive. This parameter should be set to a value other than 0 to prevent unauthorised access to the drive. When a
value has been set, it cannot be seen to prevent the security code from being read (a value of 0 is displayed). If a value has been set, the security code
must be entered before any parameter can be adjusted via the keypad, but see also UserSecurityStatus (11.044).
Parameter 11.031 User Drive Mode
Short description Defines the mode of the drive
Mode Openloop
Minimum 1 Maximum 2
Default Units
Type 8 Bit Volatile Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE, ND, NC, PT
Value Text
1 OPEn.LP
2 RFC-A
Select the drive mode on drive reset. The drive must be inactive (DriveActive (10.002) = 0) to take effect.
This parameter will change DriveMode (11.084) to the active mode.
Parameter 11.032 Maximum Heavy Duty Rating
Short description Displays the maximum heavy duty current rating of the drive
Mode Openloop
Minimum 0.00 Maximum 9999.99
Default Units A
Type 32 Bit Volatile Update Rate Power-up write
Display Format Standard Decimal Places 2
Coding RO, ND, NC, PT
MaximumHeavyDutyRating (11.032) defines the maximum setting for MotorRatedCurrent that gives heavy duty operation. If
MaximumHeavyDutyRating (11.032) = MaximumRatedCurrent (11.060) then normal duty operation is not possible.
Parameter 11.033 Drive Rated Voltage
Short description Displays the voltage rating of the drive
Mode Openloop
Minimum 0 Maximum 4
Default Units
Type 8 Bit Volatile Update Rate Power-up write
Display Format Standard Decimal Places 0
Coding RO, TE, ND, NC, PT
176
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10