Parameter 08.008 Relay 1 Output State
Short description Displays the state for relay 1
Mode Openloop
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate 1ms
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
Relay1OutputState (08.008) shows the state of Relay 1, 0 = Relay open, 1 = Relay closed.
Parameter 08.011 Digital I/O 1 Invert
Short description Set to 1 to invert digital input/output 1
Mode Openloop
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 Not.Inv
1 Invert
A value of 0 or 1 in DigitalI/O1Invert (08.011) allows the I/O state to be non-inverted(0) or inverted(1) respectively.
If DigitalI/O01mode (08.031) = 0 (Input) then DigitalI/O1Invert (08.011) inverts the destination parameter DigitalIO1Source/DestinationA (08.021) or DI/O01Source/DestinationB (08.121).
If DigitalI/O01mode (08.031) = 1 (Output) then DigitalI/O1Invert (08.011) inverts DigitalI/O1State (08.001) and the voltage on the output terminal.
If DigitalI/O01mode (08.031) = 2 or 3 (Frequency or PWM output) then DigitalI/O1Invert (08.011) has no effect.
Parameter 08.012 Digital I/O 2 Invert
Short description Set to 1 to invert digital input/output 2
Mode Openloop
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 Not.Inv
1 Invert
A value of 0 or 1 in DigitalI/O2Invert (08.012) allows the input state to be non-inverted(0) or inverted(1) respectively.
DigitalI/O2Invert (08.012) inverts the destination parameter DigitalIO2Source/DestinationA (08.022) or DI/O02Source/DestinationB (08.122).
Parameter 08.013 Digital Input 3 Invert
Short description Set to 1 to invert digital input 3
Mode Openloop
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 Not.Inv
1 Invert
A value of 0 or 1 in DigitalInput3Invert (08.013) allows the input state to be non-inverted(0) or inverted(1) respectively.
DigitalInput3Invert (08.013) inverts the destination parameter DigitalInput03DestinationA (08.023) or DI03DestinationB (08.123).
Parameter 08.014 Digital Input 4 Invert
Short description Set to 1 to invert digital input 4
Mode Openloop
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 Not.Inv
1 Invert
A value of 0 or 1 in DigitalInput4Invert (08.014) allows the input state to be non-inverted(0) or inverted(1) respectively.
DigitalInput4Invert (08.014) inverts the destination parameter DigitalInput04DestinationA (08.024) or DI04DestinationB (08.124).
Parameter 08.015 Digital Input 5 Invert
Short description Set to 1 to invert digital input 5
Mode Openloop
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 Not.Inv
1 Invert
A value of 0 or 1 in DigitalInput5Invert (08.015) allows the input state to be non-inverted(0) or inverted(1) respectively.