LowACAlarm (10.107) is displayed from step 2 on the figure above.
The functionality described for LowDCLinkOperation (06.077) is supported across Frames 02-09. For Frames 05 and above, the minimum supply voltage supported is 330V DC (233VAC
RMS)
Parameter 06.084 UTC Offset
Short description UTC Offset
Mode Open‑loop
Minimum -24.00 Maximum 24.00
Default 0.00 Units Hours
Type 16 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 2
Coding RW
UTCOffset (06.084) is an offset, specified in hours, applied to the selected clock source (see Date/TimeSelector (06.019)). This could be used for time zone offsets etc. The offset will be
applied to the time obtained from the selected clock source, in addition to any offset already applied to the time from that source.
Parameter 06.089 DC Injection Active
Short description Indicates when d.c. injection is active.
Mode Open‑loop
Minimum 0 Maximum 1
Default Units
Type 1 Bit User Save Update Rate 4ms
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
This flag is high when the sequencer is in the dc injection state and low for all other conditions.