Parameter 12.028 Variable Selector 2 Source 1
Short description Defines the 1st source parameter for variable selector 2
Mode Openloop
Minimum 0.000 Maximum 30.999
Default 0.000 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Standard Decimal Places 3
Coding RW, PT, BU
See VariableSelector1Source1 (12.008).
Parameter 12.029 Variable Selector 2 Source 2
Short description Defines the 2nd source parameter for variable selector 2
Mode Openloop
Minimum 0.000 Maximum 30.999
Default 0.000 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Standard Decimal Places 3
Coding RW, PT, BU
See VariableSelector1Source1 (12.008).
Parameter 12.030 Variable Selector 2 Mode
Short description Defines the mode for variable selector 2
Mode Openloop
Minimum 0 Maximum 9
Default 0 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
See VariableSelector1Source1 (12.008).
Parameter 12.031 Variable Selector 2 Destination
Short description Defines the destination parameter for variable selector 2
Mode Openloop
Minimum 0.000 Maximum 30.999
Default 0.000 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Standard Decimal Places 3
Coding RW, DE, PT, BU
See VariableSelector1Source1 (12.008).
Parameter 12.032 Variable Selector 2 Output
Short description Displays the output of variable selector 2
Mode Openloop
Minimum -100.00 Maximum 100.00
Default Units %
Type 16 Bit Volatile Update Rate 4ms write
Display Format Standard Decimal Places 2
Coding RO, ND, NC, PT
See VariableSelector1Source1 (12.008).
Parameter 12.033 Variable Selector 2 Source 1 Scaling
Short description Defines the scaling for the 1st input for variable selector 2
Mode Openloop
Minimum -4.000 Maximum 4.000
Default 1.000 Units
Type 16 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 3
Coding RW
See VariableSelector1Source1 (12.008).
Parameter 12.034 Variable Selector 2 Source 2 Scaling
Short description Defines the scaling for the 2nd input for variable selector 2
Mode Openloop
Minimum -4.000 Maximum 4.000
Default 1.000 Units
Type 16 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 3
Coding RW
See VariableSelector1Source1 (12.008).