Parameter 08.043 24V Supply Input State
Short description Displays the state for the 24V Supply Input
Mode Openloop
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
Digital Input 13 (24V Supply Input) is an external 24V supply input that is monitored and can be used as a 24V digital input if an external 24V supply is not required. The state parameter is low for the voltage
range from 0V to 17V and high for the voltage range above 18V. As the input is a power supply it will consume significant current if the level is taken above 24V when the drive is running from its internal power
supply, or at any voltage level if this input is the only power supply to the drive. The 24V Input is available on the AI SD card adaptor. The 24V alarm is triggered if 24VLossAlarmEnable (11.098) = 1 and
24VSupplyInputState (08.043) = 0.
Parameter 08.044 Keypad Stop Button State
Short description Displays the state for the Keypad Stop button
Mode Openloop
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
See KeypadRunButtonState (08.041).
Parameter 08.051 Keypad Run Button Invert/Toggle
Short description Set to invert/toggle Keypad Run Button
Mode Openloop
Minimum 0 Maximum 2
Default 0 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 Not.Inv
1 Invert
2 Toggle
When a button state is used to change a parameter (see KeypadRunButtonDestination (08.061)) the state can be used in any one of modes selected by KeypadRunButtonInvert/Toggle (08.051).
0 The parameter will be the same as the input state.
1 The parameter will be the inverse of the input state.
2 The parameter will toggle each time the state transitions from 0 to 1.
Parameter 08.052 Keypad Auxiliary Button Invert/Toggle
Short description Set to invert/toggle Keypad Auxiliary Button
Mode Openloop
Minimum 0 Maximum 2
Default 0 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 Not.Inv
1 Invert
2 Toggle
When a button state is used to change a parameter (see KeypadAuxiliaryButtonDestination (08.062)) the state can be used in any one of modes selected by KeypadAuxiliaryButtonInvert/Toggle (08.052).
0 The parameter will be the same as the input state.
1 The parameter will be the inverse of the input state.
2 The parameter will toggle each time the state transitions from 0 to 1.
Parameter 08.053 24V Supply Input Invert
Short description Set to invert 24V Supply Input
Mode Openloop
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Drive reset read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 Not.Inv
1 Invert
When a button state is used to change a parameter (see 24VSupplyInputDestination (08.063)) the state can be used in any one of modes selected by 24VSupplyInputInvert (08.053).
0 The parameter will be the same as the input state.
1 The parameter will be the inverse of the input state.
Parameter 08.061 Keypad Run Button Destination
Short description Defines the destination parameter for digital input 11
Mode Openloop
Minimum 0.000 Maximum 30.999
Default 0.000 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Standard Decimal Places 3
Coding RW, DE, PT
This destination parameter provides the routing for the Keypad Run (DI 11) input, see KeypadRunButtonInvert/Toggle (08.051).
118
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10