LogicFunction2Source2 (09.016) defines input source 2 of logic function 2.
Parameter 09.017 Logic Function 2 Source 2 Invert
Short description Set to invert input 2 of logic function 2
Mode Openloop
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 0
Coding RW
Setting LogicFunction2Source2Invert (09.017) inverts input 2 of logic function 2.
Parameter 09.018 Logic Function 2 Output Invert
Short description Set to invert the ouptut of logic function 2
Mode Openloop
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 0
Coding RW
Setting LogicFunction2OutputInvert (09.018) inverts the output of logic function 2.
Parameter 09.019 Logic Function 2 Delay
Short description Defines the output delay of logic function 2
Mode Openloop
Minimum -25.0 Maximum 25.0
Default 0.0 Units s
Type 16 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 1
Coding RW
LogicFunction2Delay (09.019) defines the delay at the output of logic function 1. If LogicFunction2Delay (09.019) is positive then the output does not
become 1 until the input to the delay has been at 1 for the delay time. If LogicFunction2Delay (09.019) is negative then the output remains at 1 until
the input to the delay has been 0 for the delay time.