Menu 21 − Motor 2 Parameters
Mode: Open‑loop
If SelectMotor2Parameters (11.045) = 1 then the motor set-up parameters given in the table below are used instead of the equivalent parameters in
other menus. The motor 2 parameters have the same attributes etc. as the equivalent parameters in other menus.
Parameter Motor map 2 parameter Equivalent parameter
21.001 M2MaximumSpeed (21.001) MaximumSpeed (01.006)
21.002 M2MinimumSpeed (21.002) MinimumSpeed (01.007)
21.003 M2ReferenceSelector (21.003) ReferenceSelector (01.014)
21.004 M2AccelerationRate1 (21.004) AccelerationRate1 (02.011)
21.005 M2DecelerationRate1 (21.005) DecelerationRate1 (02.021)
21.006 M2MotorRatedFrequency (21.006) MotorRatedFrequency (05.006)
21.007 M2MotorRatedCurrent (21.007) MotorRatedCurrent (05.007)
21.008 M2MotorRatedSpeed (21.008) MotorRatedSpeed (05.008)
21.009 M2MotorRatedVoltage (21.009) MotorRatedVoltage (05.009)
21.010 M2MotorRatedPowerFactor (21.010) MotorRatedPowerFactor (05.010)
21.011 M2NumberOfMotorPoles (21.011) NumberOfMotorPoles (05.011)
21.012 M2StatorResistance (21.012) StatorResistance (05.017)
21.014 M2TransientInductance (21.014) TransientInductance (05.024)
21.015 Motor2Active (21.015) N/A
21.016 M2MotorThermalTimeConstant1 (21.016) MotorThermalTimeConstant1
21.022 M2CurrentControllerKpGain (21.022) CurrentControllerKpGain (04.013)
21.023 M2CurrentControllerKiGain (21.023) CurrentControllerKiGain (04.014)
21.024 M2StatorInductance (21.024) StatorInductance (05.025)
21.027 M2MotoringCurrentLimit (21.027) MotoringCurrentLimit (04.005)
21.028 M2RegeneratingCurrentLimit (21.028) RegeneratingCurrentLimit (04.006)
21.029 M2SymmetricalCurrentLimit (21.029) SymmetricalCurrentLimit (04.007)
21.033
M2LowFrequencyThermalProtectionMode
(21.033)
LowFrequencyThermalProtectionMode
(04.025)
Parameter 21.001 M2 Maximum Speed
Short description Defines the maximum reference clamp for motor map 2
Mode Open‑loop
Minimum −VM_POSITIVE_REF_CLAMP Maximum VM_POSITIVE_REF_CLAMP
Default See exceptions below Units Hz
Type 32 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 2
Coding RW, VM
Region Default Value
50Hz 50.00
60Hz 60.00
This is the motor map 2 equivalent parameter for MaximumSpeed (01.006).
Parameter 21.002 M2 Minimum Speed
Short description Defines the minimum reference clamp for motor map 2
Mode Open‑loop
Minimum −VM_NEGATIVE_REF_CLAMP2 Maximum VM_NEGATIVE_REF_CLAMP2
Default 0.00 Units Hz
Type 32 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 2
Coding RW, VM
This is the motor map 2 equivalent for MinimumSpeed (01.007).
Parameter 21.003 M2 Reference Selector
Short description Defines which reference is used for motor map 2
Mode Open‑loop
Minimum 0 Maximum 6
Default 0 Units
Type 8 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 0
Coding RW, TE