Parameter 12.014 Variable Selector 1 Source 2 Scaling
Short description Defines the scaling for the 2nd input for variable selector 1
Mode Openloop
Minimum -4.000 Maximum 4.000
Default 1.000 Units
Type 16 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 3
Coding RW
See VariableSelector1Source1 (12.008).
Parameter 12.015 Variable Selector 1 Control
Short description Defines the control for variable selector 1
Mode Openloop
Minimum 0.00 Maximum 100.00
Default 0.00 Units
Type 16 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 2
Coding RW
See VariableSelector1Source1 (12.008).
Parameter 12.016 Variable Selector 1 Enable
Short description Enables variable selector 1
Mode Openloop
Minimum 0 Maximum 1
Default 1 Units
Type 1 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 0
Coding RW, BU
See VariableSelector1Source1 (12.008) for more details. VariableSelector1Enable (12.016) and VariableSelector2Enable (12.036) have a default of 1 so that if these parameters are not used
the variable selectors will still function.
Parameter 12.023 Threshold Detector 2 Source
Short description Defines the source paramter for threshold detector 2
Mode Openloop
Minimum 0.000 Maximum 30.999
Default 0.000 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Standard Decimal Places 3
Coding RW, PT, BU
See ThresholdDetector1Output (12.001).
Parameter 12.024 Threshold Detector 2 Level
Short description Defines the reference level for threshold detector 2
Mode Openloop
Minimum 0.00 Maximum 100.00
Default 0.00 Units %
Type 16 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 2
Coding RW
See ThresholdDetector1Output (12.001).
Parameter 12.025 Threshold Detector 2 Hysteresis
Short description Defines the hysteresis for threshold detector 2
Mode Openloop
Minimum 0.00 Maximum 25.00
Default 0.00 Units %
Type 16 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 2
Coding RW
See ThresholdDetector1Output (12.001).
Parameter 12.026 Threshold Detector 2 Output Invert
Short description Set to 1 to invert the output of threshold detector 2
Mode Openloop
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 0
Coding RW
See ThresholdDetector1Output (12.001).
Parameter 12.027 Threshold Detector 2 Destination
Short description Defines the destination parameter for threshold detector 2
Mode Openloop
Minimum 0.000 Maximum 30.999
Default 0.000 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Standard Decimal Places 3
Coding RW, DE, PT, BU
See ThresholdDetector1Output (12.001).
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
195