See BCBrakeRelease (12.040).
Parameter 12.050 BC Initial Direction
Short description Defines the initial direction of the brake
Mode Openloop
Minimum 0 Maximum 2
Default 0 Units
Type 8 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 Ref
1 For
2 Rev
See BCBrakeRelease (12.040).
Parameter 12.051 BC Brake Apply Through Zero Threshold
Short description Defines if the brake is applied through zero threshold
Mode Openloop
Minimum 0.00 Maximum 20.00
Default 1.00 Units Hz
Type 16 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 2
Coding RW, BU
See BCBrakeRelease (12.040).