Parameter 10.007 Above Set Frequency
Short description Indicates that the drive is running above the set frequency
Mode Openloop
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
See AtFrequencyLowerLimit (03.006).
Parameter 10.008 Rated Load Reached
Short description Indicates that rated load has been reached
Mode Openloop
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
RatedLoadReached (10.008) is set to one when the torque producing current is at or above its rated level. This condition is detected when the modulus of
PercentageLoad (04.020) is greater or equal to 100.0%. It should be noted that this is an indication based on the level of current and not torque, which means that if
field weakening is active a value of one in RatedLoadReached (10.008) does not necessarily mean that the motor is producing rated torque.
Parameter 10.009 Current limit active
Short description Indicates that the current limit is active
Mode Openloop
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
Currentlimitactive (10.009) is set to one if the current limit is active.
Parameter 10.010 Regenerating
Short description Indicates that power is being transferred from the motor to the drive
Mode Openloop
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
Regenerating (10.010) is set to one if power is being transferred from the motor to the drive
Parameter 10.011 Braking IGBT Active
Short description Indicates that the braking IGBT is active
Mode Openloop
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
BrakingIGBTActive (10.011) is set to one if the braking IGBT is active. As the braking IGBT active periods may be short, each time the braking IGBT is switched on
BrakingIGBTActive (10.011) is set to one and remains at one for at least 0.5s.
Parameter 10.012 Braking Resistor Alarm
Short description
Indicates that the braking IGBT is active and the braking resistor thermal accumulator is greater than
75%
Mode Openloop
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
BrakingResistorAlarm (10.012) is set when the braking IGBT is active and BrakingResistorThermalAccumulator (10.039) is greater than 75.00%. As the braking
IGBT active periods may be short BrakingResistorAlarm (10.012) is always held on for at least 0.5s.
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
147