Menu 5 − Motor Control
Mode: Openloop
The drive controls asynchronous machines in open loop control with respect to frequency and current. The open loop asynchronous control is further broken
down into vector and fixed boost modes.
Parameter 05.001 Output Frequency
Short description Displays the output frequency of the drive
Mode Openloop
Minimum −VM_SPEED_FREQ_REF Maximum VM_SPEED_FREQ_REF
Default Units Hz
Type 32 Bit Volatile Update Rate 16ms
Display Format Standard Decimal Places 2
Coding RO, FI, VM, ND, NC, PT
The OutputFrequency (05.001) is the sum of FinalDemandReference (03.001) and the motor slip compensation frequency.
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10