Parameter 12.005 Threshold Detector 1 Hysteresis
Short description Defines the hysteresis for threshold detector
Mode Open‑loop
Minimum 0.00 Maximum 25.00
Default 0.00 Units %
Type 16 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 2
Coding RW
See ThresholdDetector1Output (12.001).
Parameter 12.006 Threshold Detector 1 Output Invert
Short description Set to 1 to invert the output of threshold detector 1
Mode Open‑loop
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit User Save Update Rate 4ms read
Display Format Standard Decimal Places 0
Coding RW
See ThresholdDetector1Output (12.001).
Parameter 12.007 Threshold Detector 1 Destination
Short description Defines the destination parameter for threshold detector 1
Mode Open‑loop
Minimum 0.000 Maximum 30.999
Default 0.000 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Standard Decimal Places 3
Coding RW, DE, PT, BU
See ThresholdDetector1Output (12.001).
Parameter 12.008 Variable Selector 1 Source 1
Short description Defines the 1st source parameter for variable selector 1
Mode Open‑loop
Minimum 0.000 Maximum 30.999
Default 0.000 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Standard Decimal Places 3
Coding RW, PT, BU
The variable selector functions are always active even if the source and destination are not routed to valid parameters. If a source is not a valid parameter then the source value is taken as 0. The
update rate for each of the variable selector functions is always 4ms.
The following description is for variable selector 1, but variable selector 2 operates in the same way. The source parameters selected with VariableSelector1Source1 (12.008) and
VariableSelector1Source2 (12.009) are converted to a percentage value, scaled with VariableSelector1Source1Scaling (12.013) and VariableSelector1Source2Scaling (12.014) respectively
and then combined with a function defined by VariableSelector1Mode (12.010) to give VariableSelector1Output (12.012) as a percentage value. If VariableSelector1Enable (12.016) = 1 then
the function operates normally. If VariableSelector1Enable (12.016) = 0 then VariableSelector1Output (12.012) = 0.00% and any states within the function are reset (i.e. the time constant function
accumulator is held at zero). If the value of VariableSelector1Mode (12.010) is changed then all internal function state are also reset.
The table below shows the functions that can be selected with VariableSelector1Mode (12.010).