Parameter 11.054 Drive Date Code
Short description Shows the drive date code
Mode Openloop
Minimum
0
(Display: 0000)
Maximum
9999
(Display: 9999)
Default Units
Type 16 Bit Volatile Update Rate Background write
Display Format Lead Zero Pad Decimal Places 0
Coding RO, ND, NC, PT, BU
DriveDateCode (11.054) is a four-digit number in the form yyww where yy is the year and ww is the week.
Parameter 11.055 Onboard User Program: Clock Task Schedule Rate
Short description Displays the interval at which the clock task is scheduled in ms
Mode Openloop
Minimum 0 Maximum 262128
Default Units ms
Type 32 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
OnboardUserProgram:ClockTaskScheduleRate (11.055) shows the rate at which the timed task is scheduled in ms.
Parameter 11.060 Maximum Rated Current
Short description Displays the maximum rated current or normal duty rating of the drive
Mode Openloop
Minimum 0.000 Maximum 999.999
Default Units A
Type 32 Bit Volatile Update Rate Power-up write
Display Format Standard Decimal Places 3
Coding RO, ND, NC, PT
MaximumRatedCurrent (11.060) defines the variable maximum VM_RATED_CURRENT[MAX] which in turn limits the maximum MotorRatedCurrent
(05.007). Therefore Maximum MaximumRatedCurrent (11.060) is the maximum rated current for normal duty operation (if normal duty operation is
allowed); or the maximum continuous rating of the drive.
Parameter 11.061 Full Scale Current Kc
Short description Displays the full scale current Kc
Mode Openloop
Minimum 0.000 Maximum 999.999
Default Units A
Type 32 Bit Volatile Update Rate Power-up write
Display Format Standard Decimal Places 3
Coding RO, ND, NC, PT
FullScaleCurrentKc (11.061) shows the full scale current in r.m.s. Amps. If the drive current exceeds this level it will cause an over-current trip.
Parameter 11.063 Product Type
Short description Displays the core product type
Mode Openloop
Minimum 0 Maximum 255
Default Units
Type 8 Bit Volatile Update Rate Power-up write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT, BU
ProductType (11.063) shows the core product type as given in the table below. The drive could be the basic product or a derivative of the basic product
as defined by DriveDerivative (11.028).
Product Type (11.063) Core product range
0 Unidrive M600 to M800
1 Unidrive M100 to M400 & ID300 to ID302
Unidrive M200 Parameter Reference Guide