Indicates the current value of the position counter in Frequency or Encoder mode. Position is reset to 0 if PositionCounterReset (03.032) is 1.
Parameter 03.032 Position Counter Reset
Short description Set to 1 to reset the position counter
Mode Open‑loop
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, NC
When set, this parameter resets the position parameter (Position (03.029)).
Parameter 03.035 Position Scaling Numerator
Short description Defines the numerator used for scaling the pulse counter
Mode Open‑loop
Minimum 0.000 Maximum 1.000
Default 1.000 Units
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 3
Coding RW, BU
PositionScalingNumerator (03.035) and PositionScalingDenominator (03.036) are used to scale the pulse counter down to the required position units. The multiplying factor applied to the counter is
defined as:
PositionScalingNumerator (03.035) ÷ PositionScalingDenominator (03.036)
Parameter 03.036 Position Scaling Denominator
Short description Defines the denonminator used for scaling the pulse counter
Mode Open‑loop
Minimum 0.000 Maximum 100.000
Default 1.000 Units
Type 32 Bit User Save Update Rate Background
Display Format Standard Decimal Places 3
Coding RW
See PositionScalingNumerator (03.035).