EasyManua.ls Logo

Emerson unidrive m200 - Page 243

Emerson unidrive m200
279 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trip Reason
{HF01} CPU hardware fault during exception processing
{HF02} CPU memory management fault is an exception that occurs because of a memory protection related fault
{HF03}
CPU has detected a Bus Fault. A Bus Fault is an exception that occurs because of a memory related fault for an instruction or
data memory transaction. This might be from an error detected on a bus in the memory system.
{HF04}
CPU has detected a usage fault:
A Usage Fault is an exception that occurs because of a fault related to instruction execution. This includes:
an undefined instruction
an illegal unaligned access
invalid state on instruction execution
an error on exception return.
The following can cause a Usage Fault when the core is configured to report them:
an unaligned address on word and half word memory access
division by zero.
{HF05} Reserved
{HF06} Reserved
{HF07} Watchdog failure
{HF08} CPU Interrupt crash. Interrupt crash level indicated by subtrip number.
{HF09} Free store overflow
{HF10} Reserved
{HF11}
The HF11trip indicates that a non-volatile memory comms error has occurred.
Sub-
trip
Reason Recommended action
1 Non-volatile memory comms error. Hardware fault – contact the supplier of the drive.
2
EEPROM size is incompatible with
the user firmware.
After 1min the drive will go to its bootloader. Re-program drive with compatible
user firmware using UniMConnect
{HF12}
Stack overflow
Sub-trip Reason
1 User program or derivative background stack overflow
2 User program or derivative timed stack overflow
3 Main system interrupt stack overflow
4 Main system background stack overflow
{HF13} Reserved
{HF14} Reserved
{HF15} Reserved
{HF16} RTOS error (the background task has returned)
{HF17} Reserved
The HF18trip indicates that the internal flash memory has failed when writing option module parameter data. The reason for
the trip can be identified by the sub-trip number.