Symbol Description Units
R
Resistance W
R Gnd.
A distance zone resistive reach setting: Used for ground (earth) faults.
R Ph
A distance zone resistive reach setting used for Phase-Phase faults.
Rct
Secondary winding resistance W
Rl
Resistance of single lead from relay to current transformer W
Rr
Resistance of any other protective relays sharing the current transformer W
Rrn
Resistance of relay neutral current input W
Rrp
Resistance of relay phase current input W
Rs
Value of stabilizing resistor W
Rx
Receive: typically used to indicate a communication receive line/pin.
S1
Used in IEC terminology to identify the secondary CT terminal polarity: Replace by a dot when using ANSI standards.
S2
Used in IEC terminology to identify the secondary CT terminal polarity: The non-dot terminal.
t
A time delay.
t’
Duration of first current flow during auto-reclose cycle s
T1
Primary system time constant s
tfr
Auto-reclose dead time s
tIdiff
Current differential operating time s
Ts
Secondary system time constant s
Tx
Transmit: typically used to indicate a communication transmit line/pin.
V
Voltage. V
V<
An undervoltage element. V
V<1
First stage of undervoltage protection: Could be labeled 27-1 in ANSI terminology. V
V<2
Second stage of undervoltage protection: Could be labeled 27-2 in ANSI terminology. V
V>
An overvoltage element. V
V>1
First stage of overvoltage protection: Could be labeled 59-1 in ANSI terminology. V
V>2
Second stage of overvoltage protection: Could be labeled 59-2 in ANSI terminology. V
V0
Zero sequence voltage: Equals one third of the measured neutral/residual voltage. V
V1
Positive sequence voltage. V
V2
Negative sequence voltage. V
V2pol
Negative sequence polarizing voltage. V
VA
Phase A voltage: Might be phase L1, red phase.. or other, in customer terminology. V
VB
Phase B voltage: Might be phase L2, yellow phase.. or other, in customer terminology. V
VC
Phase C voltage: Might be phase L3, blue phase.. or other, in customer terminology. V
Vf
Theoretical maximum voltage produced if CT saturation did not occur V
Vin
Input voltage e.g. to an opto-input V
Vk
Required CT knee-point voltage.
IEC knee point voltage of a current transformer.
V
VN
Neutral voltage displacement, or residual voltage. V
Vn
Nominal voltage V
Vn
The rated nominal voltage of the relay: To match the line VT input. V
VN>1
First stage of residual (neutral) overvoltage protection. V
VN>2
Second stage of residual (neutral) overvoltage protection. V
Vres.
Neutral voltage displacement, or residual voltage. V
Vs
Value of stabilizing voltage V
Appendix A - Symbols and Glossary MiCOM P747
418 P747-TM-EN-1
P747-TM-EN-1.1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MiCOM P747 Agile and is the answer not in the manual?

GE MiCOM P747 Agile Specifications

General IconGeneral
BrandGE
ModelMiCOM P747 Agile
CategoryProtection Device
LanguageEnglish

Related product manuals