217
────────────────────────────────────────────────────
11.4 Command Reference
────────────────────────────────────────────────────
■ Integrated measurement data query
Synta
MEASure:INTEgrate? data1,data2,data3,data4,data5,data6,data7,
data8,data9,data10,data11,data12,data13
dat
data1 0 to 255 Voltage, current instantaneous value specification
(numerical data in NR1 format)
data2 0 to 255 Power instantaneous value specification
(numerical data in NR1 format)
data3 0 to 255 Voltage, current maximum value specification
(numerical data in NR1 format)
data4 0 to 255 Power maximum value specification
(numerical data in NR1 format)
data5 0 to 255 Voltage, current maximum value generation time
specification (numerical data in NR1 format)
data6 0 to 255 Power maximum value generation time specification
(numerical data in NR1 format)
data7 0 to 255 Voltage, current minimum value specification
(numerical data in NR1 format)
data8 0 to 255 Power minimum value specification
(numerical data in NR1 format)
data9 0 to 255 Voltage, current minimum value generation time
specification (numerical data in NR1 format)
data10 0 to 255 Power minimum value generation time specification
(numerical data in NR1 format)
data11 0 to 255 Integrated active power, integrated reactive power,
specification (numerical data in NR1 format)
data12 0 to 255 Integrated apparent power specification
(numerical data in NR1 format)
data13 0 to 255 Average value within a time period specification
(numerical data in NR1 format)
EASure:INTEgrate?