EasyManua.ls Logo

Hioki 3166 - Page 243

Hioki 3166
380 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
221
────────────────────────────────────────────────────
11.4 Command Reference
────────────────────────────────────────────────────
Functio
n
Returns data on the measurement items specified by (data1)to(data10).
Respons
e
synta
x
Headers
U1,U2,U3,Uave,I1,I2,I3,Iave
data1
P,Q,S,PF,F
data2
U1max,U2max,U3max,I1max,I2max,I3max
data3
Pmax,Qmax,Q-max,Smax,PFmax,PF-max,Fmax
data4
U1max DATE,U1max TIME,U2max DATE,U2max TIME,
U3max DATE,U3max TIME,I1max DATE,I1max TIME,
I2max DATE,I2max TIME,I3max DATE,I3max TIME,
OUTPUT DATE,OUTPUT TIME
data5
Pmax DATE,Pmax TIME,Qmax DATE,Qmax TIME,Q-max DATE,
Q-max TIME,Smax TIME,Smax DATE,PFmax DATE,PFmax TIME,
PF-max DATE,PF-max TIME,Fmax DATE,Fmax TIME,
START DATE,START TIME
data6
U1min,U2min,U3min,I1min,I2min,I3min
data7
Pmin,Qmin,Q-min,Smin,PFmin,PF-min,Fmin
data8
U1min DATE,UImin TIME,U2min DATE,U2min TIME,
U3min DATE,U3min TIME
data9
Pmin DATE,Pmin TIME,Qmin DATE,Qmin TIME,Q-min DATE,
Q-min TIME,Smin DATE,Smin TIME,PFmin DATE,PFmin TIME,
PF-min DATE,PF-minTIME,FminDATE,FminTIME
data10
Data formats
Date
Hours
Max and min data, PF
,
F
Instantaneous value
data except PF,F
yy/mm/dd
hh:mm:ss
+123.4E+0(9 characters in all)
+123.45E+0(10 characters in all)
Not
e
"qtime" for (data5) specifies the time at which this query was received.
"start" for (data6) specifies the starting time of the measurement for the
minimum/maximum values.
The message unit separator can be switched from a semicolon (";") to a
comma (",") with the "TRANsmit:SEParator" command.
Erro
r
In the following circumstances, a device dependent error is generated:
If the measurement mode is not Normal measurement mode.
In the event of a system error.
When no items at all are specified.
Exampl
e
Transmission
":MEAS:NORM? 255,0,0,0,0,0,0,0,0,0"
Inquires about "U1", "U2", "U3", "Uave", "I1", "I2", "I3" and "Iave" from the
measurement data.

Table of Contents