18.2 Measurement Range Organization Table
────────────────────────────────────────────────────
Voltage
Curren
iring mode
9291 CLAMP ON SENSOR
9298 CLAMP ON SENSOR
20.000 A 50.000 A 100.00 A 200.00 A 500.00 A
150.00 V
1-phase,2-wire
1-phase,3-wire
3-phase,3-wire,2-powe
3-phase,3-wire,3-powe
3-phase,4-wire
3.0000 kW
6.0000
6.0000
6.0000
9.0000
7.5000 kW
15.000
15.000
15.500
22.500
15.000 kW
30.000
30.000
30.000
45.000
30.000 kW
60.000
60.000
60.000
90.000
75.000 kW
150.00
150.00
150.00
225.00
300.00 V
1-phase,2-wire
1-phase,3-wire
3-phase,3-wire,2-powe
3-phase,3-wire,3-powe
3-phase,4-wire
6.0000 kW
12.000
12.000
12.000
18.000
15.000 kW
30.000
30.000
30.000
45.000
30.000 kW
60.000
60.000
60.000
90.000
60.000 kW
120.00
120.00
120.00
180.00
150.00 kW
300.00
300.00
300.00
450.00
600.00 V
1-phase,2-wire
1-phase,3-wire
3-phase,3-wire,2-powe
3-phase,3-wire,3-powe
3-phase,4-wire
12.000 kW
24.000
24.000
24.000
36.000
30.000 kW
60.000
60.000
60.000
90.000
60.000 kW
120.00
120.00
120.00
180.00
120.00 kW
240.00
240.00
240.00
360.00
300.00 kW
600.00
600.00
600.00
900.00
000.000 Wh to 999.000 Wh
001.000 kWh to 999.999 kWh
001.000 MWh to 999.999 MWh
to 999999 MWh
NOTE
8.2 Measurement Range Organization Table
The following table shows the organization of the ranges for current, voltage,
and power (active, reactive, and apparent).
* The Range Organization Table shows the full scale display value for each
measurement range.
* For the apparent power and reactive power measurement ranges, substitute
"VA" or "var" for "W" as the unit in the table.
* The display value for input at 0.4% or less of the measurement range is
suppressed to zero.
* The displayed measurement values for each range can go as high as 130% of
the range.
The display ranges for the power integration are as follows:
* Accuracy is guaranteed in the 20A-100A range for the 9298 sensor, and in all
ranges for the 9291 sensor.
For the apparent power and reactive power integration, substitute "VAh" or