307
────────────────────────────────────────────────────
18.3 Measurement Items and Calculations
────────────────────────────────────────────────────
Table 3. Integration Calculation Formulas
Reactive powe
r
measuremen
t
Display screen
When not using the reactive
power meter method
When using the reactive
power meter method
Integration 1/2 scree
n
(basic)
Active power integration during
consumption
WP:Σ(+P)/h
Active power integration during
consumption
WP:Σ(+P)/h
Apparent power integration during
consumption
WS:Σ(+S)/h
Lagging reactive power integration
WQ:Σ(+Q)/h
Reactive power integration during
consumption
Apparent power integration during
consumption
Integration 2/2
screen (detailed)
Active power integration
Consumption
:Σ(+P)/h
Active power integration
Consumption
:Σ(+P)/h
Active power integration
Regeneration
:Σ(−P)/h
Active power integration
Regeneration
:Σ(−P)/h
Active power integration Addition
:Σ(+P)/h+Σ(−P)/h
Active power integration
Addition
:Σ(+P)/h+Σ(−P)/h
Apparent power integration
Consumption
:Σ(+S)/h
Reactive power integration
Lag
:Σ(+Q)/h
Apparent power integration
Regeneration
:Σ(−S)/h
Reactive power integration
Lead
:Σ(−Q)/h
Apparent power integration Addition
:Σ(+S)/h+Σ|−S/h
Reactive power integration
Total
:Σ(+Q)/h+Σ|−Q/h
Reactive power integration (during
consumption)
Apparent power integration
(during consumption)
Demand screen
Load
factor
LF%
Average value within a time period of
the Active power integration (consumption)(Pave
)
Maximum demand value (Pavemax
)
×10
0
Usage
factor
TLF
%
Average value within a time period of
the apparent power integration (consumption)(Save
)
Transformer capacity settin
g
×10
0

Table of Contents