3.7 Address Configuration
A3-50
ME0384-4A
Chapter 3 Gateway Unit
Specifications Section
(4) Acceleration/deceleration [G]
Input the acceleration/deceleration rate at which the actuator is to travel. Use a value within the
rated range.
Take care, as it is possible to input a number larger that the catalog rated value.
Reduce the number if the object to be conveyed vibrates during acceleration/deceleration,
causing problems.
Acceleration/deceleration is rapid when the number is increased and gradual when it is
decreased.
Caution
For acceleration/deceleration, refer to "Appendix Chapter 2 Connectable Actuators", or
to the actuator catalog or instruction manual, and set so that the specified
acceleration/deceleration is not exceeded.
Input appropriate values so that excessive shock and vibration are not applied to the
actuator, in consideration of the installation conditions and the shape of the conveyed
object.
Increasing this number greatly affects the allowable payload. Also, take care as this can
cause failure.
Start position
Target position
Acceleration
0.3 G
Deceleration
0.2G
Speed
Time