2.3 Specifications
A2-9
ME0384-4A
Specifications Section
Chapter 2 System Configuration and Specifications
Item Specifications
Cable length
Motor/encoder cable: 20 m or less (10 m or less for RCD),
Motor Cable for 200V Motor: 30m or less
Encoder Cable for 200V Motor: 30m or less
SCON connection cable: 3 m or less per cable, total length of 10 m or less
EC Connection Cable: 10m or less
Field network
interface
CC-Link, CC-Link IE Field, DeviceNet, EtherCAT, EtherNet/IP, PROFIBUS-DP,
PROFINET IO
SIO interface
Teaching port
Communication method
RS485
Communication speed
9.6/19.2/38.4/57.6/115.2/230.4 kbps
USB port
Communication method
USB
Communication speed
12Mbps
Data recording
device
FRAM 256kbit (Gateway Unit, 24V Unit)
SRAM 4Mbit (200V Driver unit)
Calendar
function
Retention function: About 10 days Charging time: About 100 hours
Safety category
compatibility
B (The safety category specification can support up to 4 external circuits)
Drive-source
cutoff method
Internal Semiconductor Cutoff, External Lumping Axes Cutoff, External Axis-
Specific Cutoff
Protection
functionality
Overcurrent, abnormal temperature, encoder disconnection, overload
Preventive/
predictive
maintenance
functions
Low electrolytic capacitor capacity and low fan rotation speed