2.4 Driver Unit/Simple Absolute Unit Alarm Causes and Countermeasures
C2-13
ME0384-4A
Maintenance Section
Chapter 2 Troubleshooting
Alarm
code
Alarm name Causes/countermeasures
068
S
Driver
limited
SRAM access error
Cause: Servo monitor is not operated in the normal condition because
of noise or malfunction of consisting parts.
Countermeasure: 1) Take proper measures against noise.
2) When the servo monitoring function is not used,
set parameter No.112 Monitoring mode to 0.
3) If the operation is not improved in use of the
servo monitoring function in spite of measures
against noise, Please contact IAI.
06B
Maintenance information
data error
Cause: Maintenance information (total travel count, total travel
distance) has been lost.
Countermeasure: Contact IAI.
100~
1FF
Teaching tool alarm
[Refer to teaching tool instruction manual]