2.5 Causes and countermeasures for ELECYLINDER alarms
C2-29
ME0384-4A
Chapter 2 Troubleshooting
2.5 Causes and countermeasures for ELECYLINDER alarms
ELECYLINDER Alarm Group
The alarm groups and warnings occurred in ELECYLINDER are as show below.
For details and countermeasures, refer to the next section, "Troubleshooting by alarm groups".
Content Main content and typical countermeasures
A Overload alarm
[Content]
[Countermeasure]
Moving parts stopped abnormally.
Make sure that there are no obstructions or
B
Motor
error alarm
[Content]
[Countermeasure]
Motor abnormality occurred.
Replace the motor or controller.
C
Elecylinder control
unit
[Content]
Elecylinder control unit abnormality
occurred.
Replace the elecylinder control unit.
D
Elecylinder control
unit-encoder
abnormality
alarm
[Content]
[Countermeasure]
An abnormality occurred between the
elecylinder control unit and encoder.
Turn the power off and then on again.
If the unit still does not recover,
replace the motor or elecylinder control
E
Power supply
voltage/Power supply
capacity
[Content]
[Countermeasure]
Elecylinder control unit abnormality
occurred.
Check the power supply voltage for any
Content Main content and typical countermeasures
Warning
Maintenance
warning
[Content]
The "maintenance period" has come to
an end.
Perform maintenance for the unit.