2.3 Specifications
A2-19
ME0384-4A
Specifications Section
Chapter 2 System Configuration and Specifications
[Servo ON Delay Time Adjustment (Parameter No. 190)]
No. Name Unit Input range
Default initial value setting
190
Servo ON delay time
adjustment
ms 0 to 9,999 0
This parameter adjusts the time from when servo ON command signal SON is input until servo ON.
By shifting the timing of each actuator, instantaneous power can be suppressed when the servo
ON command is applied at the same time.
Stepper motor specification only