STRUCTURES / RINSE AFTER SALT WATER OPERATIONS 4-7
CHANGE C2 ICON A5 / MAINTENANCE MANUAL
CHAPTER 4
3. Turn the bilge pump off once bilge empties. Blot excess water with a towel. Leave floor boards
out until exposed surfaces are dry.
4. Remove the aft-most inspection panel (under the air rudder). Direct flow of water into this bay to
rinse the rudder bellcrank for one minute.
5. Replace inspection panel. Run bilge pump until bilge is empty.
6. Remove the water rudder inspection panel. Direct flow of water into bay to rinse the water rudder
bellcrank for one minute.
7. Replace inspection panel. Run bilge pump until bilge is empty.
VERIFICATION METHOD:
Task is done when all steps are complete and bilge is empty.
RELATED INFORMATION:
"Rinse After Salt Water Operations" on page 4-4
4.2.3 Wing Fold Rinse
This task describes how to perform a wing fold fresh water rinse after aircraft has been exposed to
salt water.
TASK INFORMATION:
Type of Maintenance
Line
Level of Certification
Owner/Pilot
Task Specific Training Required
No
Special Tools Required
None
Parts Required
None
Aircraft System and Number
Consumables
None
TASK INSTRUCTIONS:
1. Unlatch and pull out wing as if to fold it, but do not rotate or walk it back to tail.