3-12 INSPECTIONS / CONDITION INSPECTIONS AND 100-HOUR INSPECTIONS
ICON A5 / MAINTENANCE MANUAL CHANGE C2
RELATED INFORMATION:
"Inspect Roll Rigging" on page 9-17
"Inspect Flap Rigging" on page 9-65
"Installation of Wing Tip Lights" on page 6-55
"Inspect Wing Pins" on page 18-7
"Manual Tap Test" on page 3-55
AOA ports clear (left wing)
Inspect wiring harness routing through wing and fold tube,
security to spar
Check wing electrical connector condition
Check wingtip lights function and seal (See “Installation of
Wing Tip Lights” on page 6-55.)
Check that hardware is secure
Reinstall inspection panels (4)
(See “Removal and Installation of Inspection Panels and
Fairings” on page 3-34.)
Correct all unsatisfactory items prior to flight
S=Satisfactory, U=Unsatisfactory
S U Comments