Diagnostic aids 3-19
5026
Go Back
Previous
Next
Disk Test/Clean
Warning:This test destroys all data on the disk and should not be attempted on a good disk. This test may run
approximately 1½ hours depending on the disk size.
To run the Disk Test/Clean Test:
1. Select DEVICE TESTS in the Diagnostics Menu, and press Select ().
2. Select Disk Test/Clean, and press Select ().
Files will be lost/Go or Stop? is displayed to warn the user.
3. To exit the test immediately and return to DEVICE TESTS, press Back () or Stop ( ). To continue with
the test, press Select ().
If is selected, Disk Test/Clean/BAD:000000 00% is displayed. The screen updates periodically,
indicating the percentage of test completed and the number of bad blocks found.
4. The power indicator blinks during the test. The test can be canceled anytime during the test by pressing
Back () or Stop ( ).
• Once the test is complete, the power indicator turns on solid and a message displays.
• xxxx Bad Blocks/yyyyyy Usable is displayed if fewer than 2000 bad blocks are detected. xxxx
indicates the number of bad blocks, and yyyyyy indicates the number of usable blocks.
• xxxx Bad Blocks/Replace Disk is displayed if more than 2000 bad blocks are detected. The disk
cannot be recovered because too many bad blocks exist on the disk.
5. Press Back () or Stop ( ) to return to DEVICE TESTS.
Flash Test
This test causes the file system to write and read data on the flash to test the flash.
Warning:This test destroys all data on the flash because the flash is reformatted at the end of the test.
To run the Flash Test:
1. Select DEVICE TESTS in the Diagnostics Menu, and press Select ().
2. Select Flash Test, and press Select ().
• The power indicator blinks while the test is running.
• Flash Test/Test Passed is displayed if the test passes and the power indicator turns on solid.
• Flash Test/Test Failed is displayed if the test fails and the power indicator turns on solid.
3. Press Back () or Stop ( ) to return to DEVICE TESTS.

Table of Contents

Other manuals for Lexmark C734dn

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lexmark C734dn and is the answer not in the manual?

Lexmark C734dn Specifications

General IconGeneral
BrandLexmark
ModelC734dn
CategoryPrinter
LanguageEnglish

Related product manuals