EXTERIOR LIGHTING SYSTEM
T45
T
Terminal Voltage List (Reference)
End Of Sie
RUNNING LIGHT UNIT REMOVAL/INSTALLATION
A6E811266731W01
1. Disconnect the negative battery cable.
2. Remove the glove compartment. (See S85 GLOVE COMPARTMENT REMOVAL/INSTALLATION)
3. Remove in the order indicated in the table.
4. Install in the reverse order of removal.
End Of Sie
Terminal Signal Connected to Test condition
Voltage (V)/
Continuity
Action
A Power supply
HAZARD 10 A
fuse
Under any condition B+
• Inspect HAZARD 10 A
fuse
• Inspect related harness
D
Turn signal
flasher (LH)
Turn signal light
(LH)
Turn signal light (LH) flashes
Alternates
below 1.0 and
B+
• Inspect turn signal light
(LH)
• Inspect related harness
Hazard warning switch at on
position
Other Below 1.0
F
Flasher unit
ground
GND
Constant: inspect for
continuity to ground
Yes • Inspect GND
G
Turn signal
flasher (RH)
Turn signal light
(RH)
Turn signal light (RH) flashes
Alternates
below 1.0 and
B+
• Inspect turn signal light
(RH)
• Inspect related harness
Hazard warning switch at on
position
Other Below 1.0
H
Hazard warning
on
Hazard warning
switch
Hazard warning switch at on
position
Below 1.0
• Inspect hazard warning
switch
• Inspect related harness
Hazard warning switch at off
position
B+
I
Turn switch on/
off (RH)
Combination
switch
Ignition switch is at ON and
turn switch (RH) on
B+
• Inspect combination
switch
• Inspect related harness
Other Below 1.0
J
Turn switch on/
off (LH)
Combination
switch
Ignition switch is at ON and
turn switch (LH) on
B+
• Inspect combination
switch
• Inspect related harness
Other Below 1.0
A6E8112W154
1Nut
2 Running light unit
3 Connector
A6E8112W126