OILDYNE TRIM PUMP
SERVICE MANUAL NUMBER 28
90-863160 MAY 2000 Page 5A-17
IN/DOWN OPERATION
1. Connect a jumper wire between the positive (+) solenoid terminal and the green-white
motor lead terminal.
2. The motor should run.
73556
a
c
d
b
a-IN/DOWN Solenoid
b-Positive Terminal (+)
c-GREEN-WHITE Motor Lead Terminal
d-Jumper Wire
3. If the motor does not run, refer to Motor Repair.