EasyManua.ls Logo

Mercury BRAVO

Mercury BRAVO
597 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OILDYNE TRIM PUMP
SERVICE MANUAL NUMBER 28
90-863160 MAY 2000 Page 5A-17
IN/DOWN OPERATION
1. Connect a jumper wire between the positive (+) solenoid terminal and the green-white
motor lead terminal.
2. The motor should run.
73556
a
c
d
b
a-IN/DOWN Solenoid
b-Positive Terminal (+)
c-GREEN-WHITE Motor Lead Terminal
d-Jumper Wire
3. If the motor does not run, refer to Motor Repair.

Table of Contents

Other manuals for Mercury BRAVO

Related product manuals