Assembly - continued
3. Install the ground wire assembly and thermocouple assembly into the
heated body.
NOTE
Ensure the end of the ground wire is completely within the mating hole.
4. Lock the ground wire using a set screw. See Figure 11-5.
1. Thermocouple 2. Ground wire 3. Set screw
2
3
1
Figure 11-5 Install ground wire and thermocouple assemblies
11-5SLIMSTACK ACTUATOR
Hot Runner User Manual
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.