EasyManua.ls Logo

NEC ELECTRA ELITE IPK II - Page 315

NEC ELECTRA ELITE IPK II
642 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electra Elite IPK II Document Revision 3
System Hardware Manual 6 - 173
___________________________________________________________________________________
___________________________________________________________________________________
Table 6-67 VMP(4)/(8)-U( ) ETU Ready LED Indications shows the
status of the VMP(4)/(8)-U( ) ETU after it has been installed,
initialized, and is ready to process calls.
8.9.5 Jumper Settings
The following jumper settings apply.
LED 17, CH8 Off/On-Hook status Red for Off-Hook Not Used On-Hook
The following LEDS are also used during startup to signify:
LED 1 - BICOM driver loaded
LED 2 - Scandisk completed successfully
LED 4 - Application started successfully
After the system is up and running these LEDs are turned off, and all channels are ready to
receive calls.
When the VMP(4)/(8) fails to start, all eight channel LEDs and the BCLR LED (AP1) are on.
Table 6-66 VMP(4)/(8)-U( ) ETU LED Indications (Continued)
LED Description On Flashing Off
Table 6-67 VMP(4)/(8)-U( ) ETU Ready LED Indications
LED Description Status
LED 1, AP1
Application Software
Running without
errors
Solid Green
LED 4, CF PWR Power to the ETU Solid Red
LED 5, ICGA Live LED Blinking Red
LED 7, Shutdown Initialized
application
Solid Green
LED 8, Power Receiving KSU
power
Solid Red
J1 Setting
Pin 1 to Pin 2 IVR Integration (default)
Pin 2 to Pin 3 Not Used

Table of Contents

Other manuals for NEC ELECTRA ELITE IPK II

Related product manuals